Fan Motor Data
The charts below show approximately details of full speed, full load
current and starting current of motors used by APMG Ltd
2 Pole Motors:
Frame Size |
kW |
Efficiency (%) |
Speed (RPM) |
FL Current (A) |
Starting current (A) |
Starting Method |
IEC Standard |
71 |
0.37 |
70 |
2730 |
0.93 |
5.58 |
DOL |
IE1 |
71 |
0.55 |
71 |
2760 |
1.36 |
8.16 |
DOL |
IE1 |
80 |
0.75 |
77.4 |
2840 |
1.75 |
10.15 |
DOL |
IE2 |
80 |
1.1 |
80 |
2850 |
2.42 |
16.46 |
DOL |
IE2 |
90 |
1.5 |
81.4 |
2850 |
3.2 |
22.08 |
DOL |
IE2 |
90 |
2.2 |
83.2 |
2860 |
4.54 |
35.87 |
DOL |
IE2 |
100L |
3 |
84.6 |
2880 |
5.88 |
45.86 |
DOL |
IE2 |
112M |
4 |
86 |
2890 |
7.54 |
20.36 |
Star Delta |
IE2 |
132s |
5.5 |
87.2 |
2900 |
10.2 |
24.48 |
Star Delta |
IE2 |
132s |
7.5 |
88.1 |
2910 |
13.8 |
35.88 |
Star Delta |
IE2 |
160M |
11 |
89.4 |
2930 |
19.9 |
47.76 |
Star Delta |
IE2 |
160M |
15 |
90.9 |
2940 |
26.9 |
69.94 |
Star Delta |
IE2 |
160L |
18.5 |
90.9 |
2940 |
32.6 |
97.8 |
Star Delta |
IE2 |
180M |
22 |
91.3 |
2950 |
38.6 |
100.36 |
Star Delta |
IE2 |
200L |
30 |
92 |
2950 |
52.3 |
125.52 |
Star Delta |
IE2 |
4 Pole Motors:
Frame Size |
kW |
Efficiency (%) |
Speed (RPM) |
FL Current (A) |
Starting current (A) |
Starting Method |
IEC Standard |
71 |
0.37 |
65 |
1370 |
1.07 |
6.42 |
DOL |
IE1 |
71 |
0.55 |
67 |
1370 |
1.52 |
9.12 |
DOL |
IE1 |
80 |
0.75 |
79.6 |
1410 |
1.79 |
9.49 |
DOL |
IE2 |
80 |
1.1 |
81.4 |
1420 |
2.5 |
16.75 |
DOL |
IE2 |
90 |
1.5 |
82.8 |
1420 |
3.31 |
23.83 |
DOL |
IE2 |
90 |
2.2 |
84.3 |
1440 |
4.83 |
35.74 |
DOL |
IE2 |
100L |
3 |
85.5 |
1440 |
6.33 |
49.37 |
DOL |
IE2 |
112M |
4 |
86.6 |
1440 |
8.23 |
25.51 |
Star Delta |
IE2 |
132s |
5.5 |
87.9 |
1450 |
10.9 |
28.34 |
Star Delta |
IE2 |
132s |
7.5 |
88.7 |
1450 |
14.5 |
40.6 |
Star Delta |
IE2 |
160M |
11 |
89.8 |
1450 |
21.6 |
58.32 |
Star Delta |
IE2 |
160M |
15 |
90.6 |
1450 |
28.4 |
68.16 |
Star Delta |
IE2 |
160L |
18.5 |
91.4 |
1460 |
34.4 |
75.68 |
Star Delta |
IE2 |
180M |
22 |
91.7 |
1460 |
40.3 |
92.69 |
Star Delta |
IE2 |
200L |
30 |
92.3 |
1470 |
55.2 |
154.56 |
Star Delta |
IE2 |
Performance Data - Three phase
Enclosure - IP55
Rating - Maximum Continuous
Supply - 415 volts / 3 phase / 50 Hertz
Insulation - Class F